Part No. 29487
Genie Z-45/22
5 - 47
Service Manual - First Edition
Section 5 - Troubleshooting Flow Charts
0V
12V
0V
12V
0V
12V
0 or infinite ohms
4 to 8 ohms
12V
0V
Repair or replace the
steer microswitch in
controller handle.
Steer Right
Function
Inoperative
Be sure all other
functions operate
normally.
Machines not equipped
with oscillating axle,
disregard the steer
unloader valve
troubleshooting.
Start the engine from the
platform, press down
foot switch, hold the
steer switch right and
check volt-age at
terminal 7 on the drive
controller (blu/blk wire).
Hold the steer switch left
and check voltage at
TB32.
Repair open in blu wire
circuit from TP44 to
TB32.
Hold the steer switch
right and check voltage
at blk #32 wire on steer
valve.
Repair open in blk #32
wire circuit from TB32 to
steer valve.
Remove both wires from
steer right coil and check
resistance across coil
terminals.
Replace steer right valve
coil.
Reconnect coil wires,
hold steer switch and
check voltage at steer
unload valve.
Test and replace diode
or repair open in jumper
wire circuit from steer
right coil to steer unload
valve.
Replace steer valve.
Chart 32
Summary of Contents for Z-45/22
Page 1: ...Technical Publications First Edition Part No 29487 Service Manual Z 45 22 ...
Page 121: ...6 3 ...
Page 122: ......
Page 123: ...6 5 ...
Page 124: ...6 6 ...
Page 125: ...6 7 ...
Page 126: ...6 8 ...
Page 127: ......
Page 128: ...6 10 ...
Page 129: ...6 11 ...
Page 130: ...6 12 ...
Page 132: ...Z45 22 Hyd Index ...
Page 133: ...Z45 22 Hyd Index ...
Page 134: ...Z45 22 Hyd Index ...
Page 135: ...Z45 22 Hyd Index ...
Page 136: ...Z45 22 Hyd Index ...
Page 137: ...Z45 22 Hyd Index ...