5 - 22
Genie Z-45/22
Part No. 29487
Service Manual - First Edition
Section 5 - Troubleshooting Flow Charts
12V
yes
no
yes
no
0V
12V
0V
12V
Chart 14
Ground
Controls
Inoperative,
Platform
Controls
Operate
Normally
Be sure all other
functions operate
normally, including
platform controls.
Does the engine start
from the ground
controls?
Start the engine from the
ground controls and
check the voltage on the
center pole (red wire) of
the platform level switch.
Repair open in red
wire circuit from key
switch to function
switches.
Troubleshoot the
functions individually.
Repair open in red wire
circuit from emergency
stop button to the key
switch.
Check voltage at red
wire on ground controls
contact of the key switch
(the red wire checked
should originate at the
emergency stop button).
Check voltage at red/wht
#36 wire at ground
controls contact on the
key switch.
Check if key switch
internal cam is activating
ground contact.
Replace key switch
contact for ground
controls.
Replace key switch.
Repair open in red wire
circuit from key switch to
function switches.
0V
Summary of Contents for Z-45/22
Page 1: ...Technical Publications First Edition Part No 29487 Service Manual Z 45 22 ...
Page 121: ...6 3 ...
Page 122: ......
Page 123: ...6 5 ...
Page 124: ...6 6 ...
Page 125: ...6 7 ...
Page 126: ...6 8 ...
Page 127: ......
Page 128: ...6 10 ...
Page 129: ...6 11 ...
Page 130: ...6 12 ...
Page 132: ...Z45 22 Hyd Index ...
Page 133: ...Z45 22 Hyd Index ...
Page 134: ...Z45 22 Hyd Index ...
Page 135: ...Z45 22 Hyd Index ...
Page 136: ...Z45 22 Hyd Index ...
Page 137: ...Z45 22 Hyd Index ...