![Genie Z-45/22 Service Manual Download Page 87](http://html.mh-extra.com/html/genie/z-45-22/z-45-22_service-manual_2211963087.webp)
Part No. 29487
Genie Z-45/22
5 - 23
Service Manual - First Edition
Section 5 - Troubleshooting Flow Charts
12V
0V
yes
no
0V
12V
0V
12V
12V
0V
0V
12V
Does engine start from
the platform controls?
Start engine from the
platform, then press
down the foot switch and
check voltage at TP20.
Repair open in wht
wire circuit from foot
switch to TP20 OR
test and replace foot
switch.
Check for open in red
wire circuit from key
switch to TB19 OR
replace the key switch
platform contacts.
Chart 15
Platform
Controls
Inoperative,
Ground
Controls
Operate
Normally
Be sure all cables are
in good condition with
no kinks or abrasions.
Repair open in wht wire
circuit from TP20 to
function controllers.
Check voltage at TB19.
Check voltage at TP34
and TP25.
Repair open in red-1 and
red-2 wire circuit from
TB19 to TP34 and TP25
respectively.
Check voltage at blk wire
on platform emergency
stop button.
Replace contact on
emergency stop button.
Check voltage at TP22.
Repair open in blk wire
circuit from emergency
stop button to TP22.
Repair open in blk wire
circuit from TP22 to foot
switch OR replace foot
switch.
Summary of Contents for Z-45/22
Page 1: ...Technical Publications First Edition Part No 29487 Service Manual Z 45 22 ...
Page 121: ...6 3 ...
Page 122: ......
Page 123: ...6 5 ...
Page 124: ...6 6 ...
Page 125: ...6 7 ...
Page 126: ...6 8 ...
Page 127: ......
Page 128: ...6 10 ...
Page 129: ...6 11 ...
Page 130: ...6 12 ...
Page 132: ...Z45 22 Hyd Index ...
Page 133: ...Z45 22 Hyd Index ...
Page 134: ...Z45 22 Hyd Index ...
Page 135: ...Z45 22 Hyd Index ...
Page 136: ...Z45 22 Hyd Index ...
Page 137: ...Z45 22 Hyd Index ...