Part No. 29487
Genie Z-45/22
5 - 41
Service Manual - First Edition
Section 5 - Troubleshooting Flow Charts
2000
PSI
function
operates
12V
0V
4 to 5 ohms
0 or infinite ohms
function inoperative
less than 2000 PSI
2000
PSI
less than 2000 PSI
2000
PSI
Hold ground control
function switch and
check volts at org wire
on platform level up
function directional
valve.
Chart 26
Repair open in org wire
circuit from TB13 to
directional valve.
Remove both wires from
valve coil and check
resistance across the
coil terminals.
Platform Level
Up Function
Inoperative
Be sure all other
functions operate
normally.
If platform level up
function operates
normally from the
ground controls but not
from the platform
controls, troubleshoot
the platform control
toggle switch. See
Repair section.
If platform level up
function operates
normally from the
platform controls but
not from the ground
controls, troubleshoot
the ground control
toggle switch. See
Repair section.
Replace the coil.
Hold toggle switch right
and manually override
the level up directional
valve (push in button on
end of valve spool) OR
inter-change the valve
(item D) with a like valve
(item E).
function operates
Replace the platform
leveling directional
valve.
Install a pressure gauge
at the quick disconnect
coupling on the function
manifold and hold the
function switch.
Interchange the level up
and down
counterbalance valves in
the sandwich block.
Replace defective
counterbalance valve.
Remove the level up
function pressure line
from the manifold and
cap the port (PL1). Then,
with pressure gauge still
attached, operate the
function up.
Repair the master and/or
slave cylinder OR
replace the slave
cylinder counterbalance
valves.
Replace the directional
valve OR the manifold
has internal defects OR
one of the previous tests
was possibly overlooked
or diagnosed incorrectly.
Recheck and/or consult
Genie Industries service
department.
Check for mechanical
restrictions and/or a
condition exists in
which the cylinder
counterbalance valves
are not allowing the
cylinder to extend or
the cylinder has
internal defects.
Disconnecting
hydraulic lines or
adjusting the cylinder
counterbalance valves
in this situation can be
very dangerous
Please consult Genie
Industries service
department.
Summary of Contents for Z-45/22
Page 1: ...Technical Publications First Edition Part No 29487 Service Manual Z 45 22 ...
Page 121: ...6 3 ...
Page 122: ......
Page 123: ...6 5 ...
Page 124: ...6 6 ...
Page 125: ...6 7 ...
Page 126: ...6 8 ...
Page 127: ......
Page 128: ...6 10 ...
Page 129: ...6 11 ...
Page 130: ...6 12 ...
Page 132: ...Z45 22 Hyd Index ...
Page 133: ...Z45 22 Hyd Index ...
Page 134: ...Z45 22 Hyd Index ...
Page 135: ...Z45 22 Hyd Index ...
Page 136: ...Z45 22 Hyd Index ...
Page 137: ...Z45 22 Hyd Index ...