Service Manual - First Edition
Section 5 - Troubleshooting Flow Charts
0V
12V
0V
0V
Engine Will Not
Crank Over
Be sure the key switch
is in the appropriate
position.
Be sure the
emergency stop button
is pulled up into the on
position.
Be sure the circuit
breaker is not tripped.
Check battery voltage.
12V or more
less than 12V
Check voltage at center
terminal on start switch.
Trace circuit back
through the key switch
and emergency stop
button, repair open.
0V
12V
Hold start switch and
check voltage at either
side terminal on start
switch.
0V
Replace start toggle
switch.
12V
Hold start switch and
check voltage at terminal
#1 on CR1.
12V
Repair blk wire circuit
from start switch to CR1.
Check voltage at blk #53
on PR5.
Check voltage at
terminal #9 on CR1.
Replace CR1 relay or
relay socket.
12V
Repair open in blk #53
wire circuit from CR1 to
PR5.
0V
12V
Check voltage at output
cable terminal on PR5.
Check PR5 grounding
wire OR replace PR5
relay.
Check voltage at positive
cable terminal on starter
motor.
12V
0V
Replace cable from PR5
to starter.
Check starter ground
cable OR repair or
replace starter.
Kubota Models: Check
black jumper wire
connecting positive
cable terminal and
starter bendix terminal.
Check battery condition
OR check alternator OR
check fro short circuits
OR check battery cables
OR replace the battery.
Chart 1
Summary of Contents for Z-45/22
Page 1: ...Technical Publications First Edition Part No 29487 Service Manual Z 45 22 ...
Page 121: ...6 3 ...
Page 122: ......
Page 123: ...6 5 ...
Page 124: ...6 6 ...
Page 125: ...6 7 ...
Page 126: ...6 8 ...
Page 127: ......
Page 128: ...6 10 ...
Page 129: ...6 11 ...
Page 130: ...6 12 ...
Page 132: ...Z45 22 Hyd Index ...
Page 133: ...Z45 22 Hyd Index ...
Page 134: ...Z45 22 Hyd Index ...
Page 135: ...Z45 22 Hyd Index ...
Page 136: ...Z45 22 Hyd Index ...
Page 137: ...Z45 22 Hyd Index ...