Part No. 29487
Genie Z-45/22
5 - 19
Service Manual - First Edition
Section 5 - Troubleshooting Flow Charts
12V
0V
0V
12V
moves freely
solenoid
binds
OK
Chart 11
At platform controls,
start engine and switch
rpm select switch to
maintained low idle
(turtle symbol). Check
volts at blk/red wire on
rpm select switch.
Isolate the platform and
ground rpm switches,
check individually and
replace defective switch.
Engine Low
Idle Inoperative
- Diesel Models
Check if mechanical
linkage from 2-speed
solenoid to fuel
injection pump is
binding or defective.
Check voltage at the red
wire on the 2-speed
solenoid.
Replace PR2 relay.
Check if 2-speed
solenoid moves in and
out freely.
Check linkage or replace
solenoid.
Check adjustment of
linkage and fuel injection
pump low idle (see
Maintenance section).
See Kubota workshop
manual to troubleshoot
fuel injection pump.