5 - 16
Genie Z-45/22
Part No. 29487
Service Manual - First Edition
Section 5 - Troubleshooting Flow Charts
2 to 3 ohms
0V
12V
OK
bad
0V
6 to 7V
0 or infinite ohms
CHART 8
Check resistance across
governor actuator
terminals.
Continued from the
previous page.
Replace governor
actuator.
Check voltage at
terminal #1 on electronic
governor.
Repair open in wht wire
circuit from PR1 to
electronic governor.
Check electronic
governor green
grounding wire (terminal
2).
Repair open in green
wire grounding circuit.
Check voltage at
governor terminal 3
(yellow wire).
Repair open in yellow
wire circuit from ignition
module to electronic
governor.
Reconnect all wires and
see Maintenance section
for governor adjustments
OR replace electronic
governor.