Genie Z-45/22
Part No. 29487
Service Manual - First Edition
Section 5 - Troubleshooting Flow Charts
less than 1200 PSI
1200 PSI
1200 PSI
less than 1200 PSI
Continued from the
previous page.
CHART 17
Interchange secondary
relief valve (item U) with
like valve (item T). Hold
secondary down function
and recheck pressure.
Replace defective valve.
If secondary boom is in
stowed position, remove
and plug the secondary
down high pressure line
from the cylinder on the
fuel tank side of the
machine. Hold
secondary down function
and recheck pressure.
Repair both secondary
function cylinders.
Internal defect in
manifold OR one of the
previous tests involving
the pump or manifold
components was
possibly overlooked or
diagnosed incorrectly.
Recheck and/or consult
Genie Industries service
department.