Appendix
Consistency test
2018-9015-003
03-2015
13.5
Consistency test
GEA Houle determined the following method to verify if the viscosity of the liquid
manure is suitable for this product.
1. Set a pail on a level surface and install a 60 cm round plate at the center of
the pail.
2. Fill a second pail with homogenized liquid manure and slowly pour it in the
center of the plate until it overflows all around the plate. Remain close to the
plate when pouring the liquid manure.
3. Wait for one minute.
4. Measure the thickness of the liquid manure at the center of the plate.