B-26
MIWII Directional Power Protection System
GEK-113308
B.8 MODBUS MAP- STATUS
APPENDIX B
B
B.8.1.2 MOTOROLA FORMAT
ADDRESS
BIT
NAME
DESCRIPTION
LENGTH
FORMAT
027F
Date & Time
Date & Time
6
DATE/TIME
0282
Firmware Rev
Firmware Rev
6
BYTES ARRAY
0285
Order Code
Order Code
16
BYTES ARRAY
028D
Relay Name
Relay Name
16
BYTES ARRAY
029A
Last phase trip
Z2
4
BYTES ARRAY
029C
Last trip current
Z3
4
FLOAT32(INTEL)
029E
Z4
Z4
4
FLOAT32(INTEL)
02A0
Z5
Z5
4
FLOAT32(INTEL)
02A4
LTU Date & Time
f h
6
DATE/TIME
02AB
8
40 Blocked
Blq 40
2
BIT
02AB
11
32_1 Blocked
Blq 32 1
2
BIT
02AB
13
32_2 Blocked
Blq 32 2
2
BIT
02AB
15
32_3 Blocked
Blq 32 3
2
BIT
02AC
0
Trip LED
LD
2
BIT
02AC
1
READY
LR
2
BIT
02AC
2
LED 1
L1
2
BIT
02AC
3
LED 2
L2
2
BIT
02AC
4
LED 3
L3
2
BIT
02AC
5
LED 4
L4
2
BIT
02AC
8
Logic 1
c1
2
BIT
02AC
9
Logic 2
c2
2
BIT
02AC
10
Logic 3
c3
2
BIT
02AC
11
Logic 4
c4
2
BIT
02AD
8
TRIP
d
2
BIT
02AD
9
ALARM
al
2
BIT
02AD
10
Output 1
Output 1
2
BIT
02AD
11
Output 2
Output 2
2
BIT
02AD
12
Output 3
Output 3
2
BIT
02AD
13
Output 4
Output 4
2
BIT
02AD
14
Input 1
Input 1
2
BIT
02AD
15
Input 2
Input 2
2
BIT
02AE
1
Sett. change disable
EDICAJ
2
BIT
02AE
6
Group change
EDCTAB
2
BIT
02AE
9
Breaker Closed
EST52
2
BIT
02AE
11
40 Voltage inhibit
INH V 40
2
BIT
02AE
12
Fuse Failure
DIS FUSE FAL
2
BIT
02AE
14
EEPROM failure
F1
2
BIT
02AE
15
User Settings
AU
2
BIT
02AF
3
ACTIVE GROUP
T AC
2
BIT
02AF
4
Frequency
frec
2
BIT
02AF
5
Local
LOCREM
2
BIT
02B4
0
40 Circle 1 Pickup
ARR 40 1
2
BIT
02B4
1
40 Circle 2 Pickup
ARR 40 2
2
BIT
02B4
2
32_1 Alarm Pickup
ARR Alr 32 1
2
BIT
02B4
3
32_1 Pickup
ARR 32 1
2
BIT
02B4
4
32_2 Alarm Pickup
ARR Alr 32 2
2
BIT
02B4
5
32_2 Pickup
ARR 32 2
2
BIT
02B4
6
32_3 Alarm Pickup
ARR Alr 32 3
2
BIT
02B4
7
32_3 Pickup
ARR 32 3
2
BIT
02B4
15
General Pickup
ARRGEN
2
BIT