Chapter 6
Testing
75
Watchdog on/off
The system watchdog monitors low-level system communication between system software
and hardware. If communication is interrupted for a period of 20 minutes, the watchdog
process will shut down and restart the DVR.
Opening the MV4 Monitor program requires stopping low-level communication and
therefore automatically turns off the watchdog.
Watchdog On
and
Off
buttons control
watchdog operation. To indicate the Watchdog is off, the front panel’s software LEDs
rapidly flash. There is no external indication when the watchdog is running.
When active, the watchdog communicates via COM 1. COM 1 data activity is indicated by
COM LED 1 on the DVR’s front panel.
LEDs and relays
You may test the software LEDs via the MV4 Monitor program. Check the appropriate box
for the LED to test and press send (
). The LED will light up momentarily and
subsequently extinguish.
You may also test the relays. Select the relay to activate and click
Send
(
page 76). Relay activation is generally audible, but no external display indicates relay
status.
Figure 58. LEDs
Summary of Contents for MobileView 4
Page 1: ...MobileView g MobileView 4 Installation Manual ...
Page 16: ...MobileView 4 Installation Manual 6 ...
Page 44: ...MobileView 4 Installation Manual 34 Figure 29 Commit application ...
Page 47: ...Chapter 4 DVR configuration 37 Figure 32 Vehicle setup ...
Page 59: ...Chapter 4 DVR configuration 49 Figure 38 Alarm events ...
Page 68: ...MobileView 4 Installation Manual 58 ...
Page 94: ...MobileView 4 Installation Manual 84 ...