![GE MobileView 4 Installation Manual Download Page 79](http://html.mh-extra.com/html/ge/mobileview-4/mobileview-4_installation-manual_126706079.webp)
Chapter 5
Optional hardware installation
69
•
Ensure that a jumper exists between terminals 9 and 10 on J13.
•
Connect the white negative wire (present only on the panic button with key
reset) to J13, terminal 3.
Note:
Terminal 2 on J13 is generally reserved for the impact sensor input.
Figure 54. Panic button wiring
6. Mount the panic button to the previously drilled holes.
Status LEDs
Your MobileView provides LEDs for status indication. When the green LED is on and red
LED is off, the system is functioning properly. When the red LED is on, it indicates the
system needs service.
MSS-4008-00-00
Green
Red
Yellow
Yellow
Gray
J13.11 - 12 V fused (or any other
J1.7 - Software
J1.8 - Camera
J13.1 - Digital input 1
(available 12V) terminal)