March 2008
1-32
Programming Site Data
Entering Volumetric Data
5.
Use the
[F1]-[F4]
and [
→]
keys to select the desired
Volumetric
Units
for the flow rate display.
The abbreviations and definitions of all the available volumetric and
totalizer units are shown in Table 1-7 below. The choices shown on
the option bar are determined by the selection made at the previous
SYSTEM UNITS
screen.
6.
Use the
[F1]-[F4]
keys to select the
Volumetric Time
(units for the
volumetric flow rate display).
7.
Use the
[F1]-[F4]
keys to select the
Vol Decimal Digits
(the desired
number of digits to the right of the decimal point) in the
volumetric flow rate display.
Entering Totalizer Data
8.
Use the
[F1]-[F4] and
[
→]
keys to select the
Totalizer Units.
The abbreviations and definitions of all the available volumetric and
totalizer units are shown in Table 1-7 above. The choices shown on
the option bar are determined by the selection made at the previous
SYSTEM UNITS
prompt screen.
9.
Use the
[F1]-[F4]
keys to select the
Total Decimal Digits
(the
desired number of digits to the right of the decimal point) in the
totalized flow display.
Table 1-7: Available Volumetric/Totalizer Units
English
Metric
Actual Units
ACF = Actual Cubic Feet
ACM = Actual Cubic Meters
KACF = Thousands of ACF
KACM = Thousands of ACM
MMACF = Millions of ACF
MMACM = Millions of ACM
Standard Units
SCF = Standard Cubic Feet
SCM = Standard Cubic Meters
KSCF = Thousands of SCF
KSCM = Thousands of SCM
MMSCF = Millions of SCF
MMSCM = Millions of SCM
Summary of Contents for DigitalFlow GS868
Page 7: ...Chapter 1 ...
Page 59: ...Chapter 2 ...
Page 77: ...Chapter 3 ...
Page 90: ...Chapter 4 ...
Page 104: ...Chapter 5 ...
Page 110: ...Chapter 6 ...
Page 122: ...Appendix A ...
Page 131: ...Appendix B ...
Page 132: ...Data Records Option Cards Installed B 1 Initial Setup Data B 2 ...
Page 136: ...Appendix C ...
Page 156: ...Appendix D ...