Electromagnetic Compatibility: Electromagnetic Compatibility (EMC)
Guidance and Manufacturer’s Declaration – Electromagnetic
Immunity
The 250cx Series Maternal/Fetal Monitor is intended for use in the electromagnetic
environment specified below. It is the responsibility of the customer or user to
assure that the 250cx Series Maternal/Fetal Monitor is used in such an environment.
NOTE:
U
t
is the AC mains voltage prior to application of the test level.
Immunity Test
EN 60601 Test Level
Compliance Level
Electromagnetic Environment – Guidance
Electrostatic
Discharge (ESD)
EN 61000-4-2
± 6 kV contact
± 6 kV contact
Floors should be wood, concrete or ceramic tile. If
floors are covered with synthetic material, the relative
humidity should be at least 30%.
± 8 kV air
± 8 kV air
Electrical Fast
Transient/Burst
EN 61000-4-4
± 2 kV for power supply lines
± 2 kV for power supply
lines
Mains power should be that of a typical commercial
or hospital environment.
±1 kV for input/output lines
±1 kV for input/output
lines
Surge
EN 61000-4-5
± 1 kV differential mode
± 1 kV differential mode
Mains power should be that of a typical commercial
or hospital environment.
± 2 kV common mode
± 2 kV common mode
<5% U
t
(>95% dip in U
t
)
for 0.5 cycles
<5% U
t
(>95% dip in U
t
)
for 0.5 cycles
Voltage dips, short
interruptions and
voltage variations
on power supply
input lines
EN 61000-4-11
<40% U
t
(>60% dip in U
t
)
for 5 cycles
<40% U
t
(>60% dip in
U
t
) for 5 cycles
Mains power should be that of a typical commercial
or hospital environment. If the user of the equipment
requires continued operation during power mains
interruptions, it is recommended that the equipment
be powered from an uninterruptible power supply or
a battery.
<70% U
t
(>30% dip in U
t
)
for 25 cycles
<70% U
t
(>30% dip in
U
t
) for 25 cycles
<5% U
t
(>95% dip in U
t
)
for 5 s
<5% U
t
(>95% dip in U
t
)
for 5 s
Power Frequency
(50/60 Hz)
Magnetic Field
EN 61000-4-8
3 A/m
3 A/m
Power frequency magnetic fields should be at levels
characteristics of a typical location in a typical
commercial or hospital environment.
Summary of Contents for Corometrics 250cx Series
Page 2: ......
Page 6: ...CE CE ii 0086 ...
Page 14: ...viii 250cx Series Maternal Fetal Monitor Revision C 2036947 001 ...
Page 16: ...1 2 250cx Series Maternal Fetal Monitor Revision C 2036947 001 For your notes ...
Page 29: ...Revision C 250cx Series Maternal Fetal Monitor 2 1 2036947 001 2 Equipment Overview ...
Page 30: ...2 2 250cx Series Maternal Fetal Monitor Revision C 2036947 001 For your notes ...
Page 55: ...3 1 250cx Series Maternal Fetal Monitor Revision C 2036947 001 3 Installation ...
Page 56: ...3 2 250cx Series Maternal Fetal Monitor Revision C 2036947 001 For your notes ...
Page 81: ...Revision C 250cx Series Maternal Fetal Monitor 4 1 2036947 001 4 Maintenance ...
Page 82: ...4 2 250cx Series Maternal Fetal Monitor Revision C 2036947 001 For your notes ...
Page 141: ...Revision C 250cx Series Maternal Fetal Monitor 5 1 2036947 001 5 Troubleshooting ...
Page 142: ...5 2 250cx Series Maternal Fetal Monitor Revision C 2036947 001 For your notes ...
Page 194: ...6 2 250cx Series Maternal Fetal Monitor Revision C 2036947 001 For your notes ...
Page 237: ...Revision C 250cx Series Maternal Fetal Monitor B 1 2036947 001 B Alarms Summary ...
Page 238: ...B 2 250cx Series Maternal Fetal Monitor Revision C 2036947 001 Alarms Summary For your notes ...
Page 251: ......