© 2019 Baker Hughes, a GE company, LLC. All rights reserved.
68
|
BHGE
Incorrect polarity connection results in an effectively closed
connection.
Consult with qualified personnel to ensure that electrical
requirements for the switches are met.
The maximum voltage that can be applied to the digital switch outputs is 30 VDC. This is an
open circuit parameter (the digital switch is in the open state). Under open circuit conditions,
the switch current will be less than 0.200 mA.
The switch maximum current rating is 1 A. When the switch is ON, the typical switch voltage is
1V.
When the switch is on (closed) the external voltage must be dropped across the load
(Figure 35).
CAUTION
The load must be designed such that the current in the circuit is
1 A at all times. Some 3rd party devices, such as incandescent
lamps or solenoids, require surge and back EMF protection to
prevent voltage spikes.
Inductive Load, Solenoid, Incandescent Lamp Configuration
Figure 35 Switch Installation Drawing: Correct Configuration with Load
CAUTIONS
SVI FF Switch Output:
1 V
with switch ON
External
Voltage
Source
LOAD
Load is designed to limit current through the switch to < 1 A.
+
-
If the load is inductive (solenoid,
incandescent lamp, etc.), then install a
Freewheel or Flyback diode to prevent
switch damaging EMF voltage spikes.
+
-
Summary of Contents for Baker Hughes Masoneilan SVI FF
Page 12: ...This page intentionally left blank ...
Page 72: ...This page intentionally left blank ...
Page 82: ...This page intentionally left blank ...
Page 94: ...This page intentionally left blank ...
Page 108: ...This page intentionally left blank ...
Page 198: ...This page intentionally left blank ...
Page 206: ...This page intentionally left blank ...
Page 224: ...This page intentionally left blank ...
Page 228: ...This page intentionally left blank ...
Page 230: ...This page intentionally left blank ...
Page 250: ...This page intentionally left blank ...
Page 262: ...This page intentionally left blank ...
Page 263: ......