Masoneilan SVI FF Instruction Manual
=
|
147
© 2019 Baker Hughes, a GE company, LLC. All rights reserved.
Display and Clear Error Messages
Use this procedure, VIEW ERR, to view fault codes and messages listed in Table 30 of this
manual.
1. Press
+
in
NORMAL
mode to move through the options until you reach the
VIEW ERR
menu
item.
2. Press
*
to go to
VIEW ERR
menu.
3. Press
*
to display the list of status values.
4. Press
+
to move forward trough the list in sequence.
5. Press
–
to move back through the list.
6. Press
*
at any status message to return to the
VIEW ERR
option.
7. Press
+
to move to
Clear ERR
.
8. Press
*
to clear all messages.