© 2019 Baker Hughes, a GE company, LLC. All rights reserved.
48
|
BHGE
Control Sets Configuration
Table 3 and Table 4 give guidelines for configuring various actuator sizes with corresponding
control sets. Table 5 lists the FF parameters.
Table 3 Actuator Settings: Control Sets for Single Acting
Set #
Actuator
Size
Examples
1
Small
4.5" Camflex (7-15 Spring Range)
2
#6, 87(ATC), 3-15 Spring Range
#6, 88(ATO), 11-23 Spring Range
#10, 87 (ATC), 3-15 Spring Range
#10, 88(ATO), 11-23 Spring Range
3
#6, 87(ATC), 6-30 Spring Range
#6, 88(ATO), 21-45 Spring Range
#10, 87 (ATC), 6-30 Spring Range
#10, 88(ATO), 21-45 Spring Range
4
#16, 87(ATC), 3-15 Spring Range
#16, 88(ATO), 11-23 Spring Range
#23, 87 (ATC), 3-15 Spring Range
#23, 88(ATO), 11-23 Spring Range
5
Large
#16, 87(ATC), 6-30 Spring Range
#16, 88(ATO), 21-45 Spring Range
#23, 87 (ATC), 6-30 Spring Range
#23, 88(ATO), 21-45 Spring Range
Table 4 Actuator Settings: Control Sets for Double Acting
Set #
Actuator
Size
Examples
6
Small
51, #12, Rated Travel
3.75"
51, #16, Rated Travel
2"
51, #20, Rated Travel
1.25"
7
Large
51, #12, Rated Travel = 4"
51, #16, Rated Travel
2.5"
51, #20, Rated Travel
1.5"
Model 70 Camflex, Double Acting, #10
Summary of Contents for Baker Hughes Masoneilan SVI FF
Page 12: ...This page intentionally left blank ...
Page 72: ...This page intentionally left blank ...
Page 82: ...This page intentionally left blank ...
Page 94: ...This page intentionally left blank ...
Page 108: ...This page intentionally left blank ...
Page 198: ...This page intentionally left blank ...
Page 206: ...This page intentionally left blank ...
Page 224: ...This page intentionally left blank ...
Page 228: ...This page intentionally left blank ...
Page 230: ...This page intentionally left blank ...
Page 250: ...This page intentionally left blank ...
Page 262: ...This page intentionally left blank ...
Page 263: ......