![GARDTEC 872 Installation Instructions Manual Download Page 96](http://html1.mh-extra.com/html/gardtec/872/872_installation-instructions-manual_3561995096.webp)
Page
95
b)
Scenario Unlocking the initial entry door disables all means of conformation
6.4.3 DD243:2002.
Event 1
System Set
Event 2
Entry Door Unlocked
Confirmed Alarms Disabled
Event 3
Open Entry Door (entry time starts)
Event 4
Entry Time Expires (inc Entry Time 2)
Unconfirmed Alarm Transmitted
Event 5
Any subsequent zones triggered
No Confirmed Signals Transmitted
Or
Event 1
System Set
Event 2
Entry Door Forced Open (entry time starts)
Event 3
Entry Time Expires (inc Entry Time 2)
Unconfirmed Alarm Transmitted
Event 4
non entry/access Zone Triggered
Event 5
Second non entry.access Zone Triggered
Confirmed Transmitted
To achieve the above
Confirm on entry = On
ET Mode = Door Lock
Door Lock Zone programmed as ET
c)
Scenario Opening the initial entry door disables all means of conformation
6.4.4 DD243:2002.
Event 1
System Set
Event 2
Entry Door Opened (entry time starts)
Confirmed Alarms Disabled
Event 3
Entry Time Expires (inc Entry Time 2)
Unconfirmed Alarm Transmitted
Event 4
Any subsequent zones triggered
No Confirmed Signals Transmitted
To achieve the above
Confirmed on entry = Off
GardTec
872
Appendix 1
872.qxd 05/11/2003 15:01 Page 95