Control Panel Mounting
Remove the two lid securing screws (single screw on polycarbonate version see Fig1)
then (pushing in side buttons on polycarbonate version) pull the lid forwards and lift clear
of the lid securing lip. Store the lid in a safe place.
Offer the base to the wall and using it as a template mark the four fixing point noting (on
the metal version) that the lid securing lip should be at the bottom.
Store the base in a safe place then drill the wall.
Under no circumstances should you
drill through the base.
Before mounting the base to the wall remove any trunking or conduit entries that you
require as knockouts.
Mount the base to the wall using 30mm No.10 screws and suitable rawl plugs.
After the installation has been completed refit the lid and secure with the retaining
screw(s).
Keypad Mounting
The standard GardTec
800 Series
keypad is available with a 32 character LCD display
or with a twin seven segment LED display. All these keypads require the GardTec
800
Series
RKP Housing Part No. 01-063 unless the keypad is to be mounted within the
polycarbonate control panel (see Fig 1). Contour keypads are supplied as a complete
unit for remote mounting.
This housing has been designed to allow mounting in one of three positions. These are:-
With the hinged flap to the left.
(See Fig 2a.)
Use fixing points A, B, D, E
placing edge of board under tab F
With the hinged flap to the right.
(See Fig 2b.)
Use fixing points A, C, D, E
With the hinged flap to the bottom. (See Fig 3.)
Use fixing points A, B, D, E
placing edge of board under
tab G
The base of the housing should be fixed to the wall using 25mm x No.8 screws and
suitable rawl plugs in three positions.
After the keypad has been mounted in the base, the correct spring (supplied with the
keypad) should be pushed onto the tamper switch (see Figs 2 & 3 for spring details).
Before replacing the cover move the ident jumper to the correct position.
Provided that the panel is mounted horizontally the keypad may also be mounted
onboard the polycarbonate control panel (see Fig1) by removing the keypad blanking
plate in the control panel cover. It should be noted that any zone expanders, ID
expanders or output expanders cannot be fitted onboard if this option is chosen.