![GARDTEC 872 Installation Instructions Manual Download Page 59](http://html1.mh-extra.com/html/gardtec/872/872_installation-instructions-manual_3561995059.webp)
Latch Any
Will activate when panel is set and will reset when entry timer starts
Any Set
Will activate when panel is set and will reset when panel is unset
Power Fail
Will activate when aux. power falls below 10.6 volts
Power OK
Output is active and changes over when the battery volts fall below 10.6 V
Watchdog
Will activate when the processor is reset
Mails Fail
Will Activate when the mains is removed from the panel and will reset when the mains
is restored
Any Digi
Will activate when any Digicom channel is triggered
Status
This output has 3 operating modes intended to provide visual indication of system
status
Set output on for 10 seconds
Unset On for 1 second Off for 1 second for a 10 second period
Confirmed On for 3 seconds Off for 1 second until the system is reset.
Perimeter
Will activate when a perimeter zone is triggered
Zone Exclude
Will activate when the panel auto rearms with a zone in fault condition
Custom 1-8
This output can be used to follow a zone or code
Timed 1-3
This output will follow the programmed On /Off times for times 1/2/3
Any Closed
This output will change over when any area is set
Page
58
GardTec
872
Areas, Zones & Output Types
872.qxd 05/11/2003 15:01 Page 58