Alarm B
Will activate when a second zone has alarmed (The activation of this output is
dependent upon other system attributes) Please refer to the DD243 Section within this
manual.
Alarm Abort
Will activate when the panel is in alarm and unset within the programmed abort time .
Power Fail
Will activate when aux. power falls below 10.6 volts.
Watchdog
Will activate when the processor is reset.
Mails Fail
Will Activate when the mains is removed from the panel and will reset when the mains
is restored.
Area 1-7 Alarm
Will activate when the selected area is in alarm and will reset when the panel auto re-
arms or when the panel is reset.
O/C Area 1-7
Will activate when the selected area is set and unset.
O/C Cleaner
Used for sending open and closing when a cleaner code is used.
Area 1-7 Alarm B
Will activate when a second zone has alarmed in the selected area (The activation of
this output is dependent upon other system attributes) Please refer to the DD243
Section within this manual.
Alarm Abort 1-7
Will activate when the selected area is in alarm and unset within the programmed abort
time.
Area 1-7 Panic
Will activate when the selected area panic zone is triggered will also activate when a
area duress code is entered.