With the exception of the mains wiring all
interconnections should be made with multicore 7/.02 alarm cable.
Good wiring practice should be observed throughout the installation and the following
tips may prove useful.
Never run alarm cables parallel to mains cables, telephone cables or any
other cables that may be carrying inductive loads
Whenever you have to cross mains cables with alarm cables ensure that you
do so at 90°
Always wire the mains connection for the control panel back to the
consumer unit via a 3A fused spur.
Never tap into ring main circuits that have fridges/freezers on them.
Never tap into lighting circuits that have fluorescent lighting units on them.
Mains Supply Connection
Mains Wiring only to be carried out by suitably qualified personnel.
The mains connection for the GardTec
872
should be as shown in Fig 6.
Fig 6.
Warning the
GardTec
872
control
panel MUST
BE
EARTHED.
It should not be possible for mains wiring to touch low voltage wiring
Consumer Unit
3A Unswitched
Fused Spur
Control Panel Mains
Terminal Block
Mains (Twin & Earth)
Connection Colours
Live
=
Red
Neutral =
Black
Earth
=
Copper
Yellow/Green sleeving should be
used for Copper Earth Conductor
L
E
N
125mA Anti Surge Fuse