37
System Setting
Event Setup
Define various events, and specify the conditions to notify the user in various ways.
Alarm Out
Specify the alarm output conditions with the work schedule.
Number of alarm output is different on each models.
Model
Relay output
Alarm (TTL) output
DR-4FX1
1
N/A
DR-8FX2
1
N/A
DR-16FX2
1
N/A
DR-8FX5
4
4
DR-16FX5
8
8
1. From
<SYSTEM SETUP> - <EVENT>
, select
<ALARM OUT>
.
2. Use the
[▲▼
◀▶
/ENTER]
buttons on the
remote control or use the mouse to select
<ALARM OUT>
and configure the related settings.
>NAME : You can rename the alarm.
>OPERATION : Set the alarm output mode.
- N/O (Normal Open) : It normally stays Open.
If an event occurs, it will switch to Close.
- N/C (Normal Close) : It normally stays Close.
If an event occurs, it will switch to Open.
>DURATION : Specify the duration of the alarm output.
- TRANSPARENT : Keep the alarm out for as much time as the event lasts.
- UNTIL KEY : Keep the alarm out until a mouse or remote control button is pressed.
- 5 ~ 300 SEC : Keep the alarm out for as long as specified.
>TEST : Forcibly output the alarm for the test purpose.
3. To apply the change, click
<APPLY>
in the bottom of the screen.
4. When done, press the
[EXIT]
button on the remote control or click
<CLOSE
> button.
The confirmation message appears and you will return to the previous menu.