Installing the HardBoot system
5
· G&D HardBoot plus
Optional: Installing a slave device
HardBoot CCX
An optional
HardBoot CCX
slave device expands an existing
HardBoot
system. The
first slave device is connected to the master device
HardBoot plus
, the further slave
devices to the respective last
HardBoot CCX
slave device.
1. Position the
HardBoot CCX
slave device above (or below) the last installed device
of the
HardBoot
system.
2. Plug the supplied
x link
connection cable into the left
x Bus
socket.
3. Connect the other end of the cable to the existing
HardBoot
system.
a. If the
HardBoot CCX
that is to be installed is the first slave device, plug the
other end of the cable into the socket
x Bus
of the master device
HardBoot plus
.
b. If there are already one or several existing slave devices in the
HardBoot
sys-
tem, connect the other end of the
x link
connection cable to the right
x Bus socket
of the last slave device.
4. The address of the new slave device within the
HardBoot
system is set through the
DIP switch 1 to 4 on the front panel of the device. If necessary, change the posi-
tions of the DIP switch to set the device address:
Figure 3: Connection of a slave devic (above) to the existing master device
Figure 4: Connection of a slave device (above) to the existing slave device
Slave device 1
Slave device 2
Slave device 3
Slave device4