DMC-1000/1500 Command Reference
BV
DMC-1500
FUNCTION:
Burn Variables
DESCRIPTION:
:
The BV command saves the controller variables in non-volatile EEPROM memory. This
command typically takes up to 2 seconds to execute and must not be interrupted. The
controller returns a : when the Burn is complete.
ARGUMENTS:
None
USAGE: DEFAULTS:
While Moving
No
Default Value
---
In a Program
Yes
Not in a Program
Yes
Can be Interrogated
No
Used in an Operand
No
RELATED COMMANDS:
BN Burn
Parameters
BP Burn
Program
Note: This command may cause the Galil software to issue the following warning "A time-out
occurred while waiting for a response from the controller". This warning is normal and is designed to
warn the user when the controller does not respond to a command within the timeout period. This
occurs because this command takes more time than the default timeout of 1 sec. The timeout can be
changed in the Galil software but this warning does not affect the operation of the controller or
software.
Note: -4MF will save arrays variables.