DMC-100/1500 Command Reference
KP
•
79
DMC-1000
DMC-1500
KP
FUNCTION:
Proportional Constant
DESCRIPTION:
KP designates the proportional constant in the controller filter. The filter transfer function is
D(z) = 4
⋅
KP + 4
⋅
KD(z-1)/z + KI z/2(z-1)
For further details see the section Theory of Operation.
ARGUMENTS:
KP x,y,z,w KPX=x KP a,b,c,d,e,f,g,h where
x,y,z,w are unsigned numbers in the range 0 to 1023.875 with a resolution of 1/8.
"?" returns the value of the proportional constant for the specified axis.
USAGE: DEFAULTS:
While Moving
Yes
Default Value
6
In a Program
Yes
Default Format
4.2
Command Line
Yes
Can be Interrogated
Yes
Used as an Operand
Yes
OPERAND USAGE:
_KPx contains the value of the proportional constant for the specified axis.
RELATED COMMANDS:
KP Proportional
Constant
KI Integrator
IL Integrator
Limit