G.Weike Laser
Profession Laser Manufacturer more than 15 Years.
21
4.3 Debugging install of Fiber laser machine
1.AC INPUT:
The socket for supply input that can be only mated with the plug on
the power cord we provided.
(
”1” on the Picture 4-8)
2. POWER:
Air switch.
(
”2” on the Picture 4-8)
3.MOD:
Modulation input, the BNC connector for switching the laser on and off
in remote control modes. The control signal should be able to apply current over
20mA, and the voltage should be 24V.
(
”3” on the Picture 4-8)
Picture 4-8
4. CTRL-INTERFACE:
Control interface, this interface is a male DB25
connector and it’s multi-functional. You can set the control mode and input
analog control signal with the interface, and fault signal is sent from it.
(
”4” on
the Picture 4-8)
5.RS-232:
RS-232 serial port, this interface is a male DB9 connector, and will be
used in hyper terminal and RS-232 mode.
(
”5” on the Picture 4-8)
6. SERVICE
: T
his Service is a female DB9 connector, the definitions of the port
is.
(
”6” on the Picture 4-8)
7. WATER:
Pipe connectors, the inlet and outlet for cooling water flow in and
return, suitable for 12 mm PU pipes. Connect the “IN” with the line which
connect with the “A1” port.Connect the “OUT” with the line which connect with
the “A2” port.(shown on the (picture 4-1 and picture 4-8).
Power Connection
A power cord is provided in the package, as in picture 4-9.
Picture 4-9