17
line according to the direction signed on the picture4-1
According to the sign of chiller shell connect the import and export pipe with
laser imports (A1) and export (A2), and pay attention to the import and export
direction, to avoid put connection wrong with import and export pipe. Before
connecting pipe, ensure that pipeline without garbage and sundries, after connecting,
there is no fold flat phenomenon at the corner.
d)
Water quality standard
Picture 4-4
Picture 4-5
Open the inlet valve which marked on the picture 4-4 , add water to the tank. In
the first time, the water better to reach the line which marked on the picture 4-5.
Water level should be lower than the top edge of water tank 100 mm to 200 mm, in
order to prevent water overflow from the tank. Water chiller are not allowed to use
the tap water,but use pure water, distilled water or deionized water, Otherwise it will
damage to water chiller’s refrigeration machine and laser’s radiator, damage
machine components. Prohibit adding any corrosive liquid or not specified brand
antifreeze into the water cooling machine.
e)
Power test
Picture4-6
Picture4-7
Open the water chiller (rotate the switch from picture4-6 to picture4-7) check