General Installation
4.6
Miscellaneous Cable Installation Notes
LH Auto / Manual
LH Raise/ Lower
RH Auto / Manual
RH Raise / Lower
N/C
Rem. Sw. Power
Rem. Sw. Ground
Use momentary toggle switches.
Left Hand Auto / Manual
Connecting Pin A to Ground toggles LH control to Manual
Connecting Pin A to Power toggles LH control to Auto
Right Hand Auto / Manual
Connecting Pin C to Ground toggles RH control to Manual
Connecting Pin C to Power toggles RH control to Auto
LH Raise / Lower
Connecting Pin B to Ground creates LH valve Lower signal
Connecting Pin B to Power creates LH valve Raise signal
RH Raise / Lower
Connecting Pin D to Ground creates RH valve to Lower signal
Connecting Pin D to Power creates RH valve Raise signal
Single LH or RH Toggle switches should be wired as LH switches.
LH or RH assignment will be selected with "Remote Config" function in the
System Setup menu.
Toggle Remote Switch Wiring
*A cable assembly with the connector wired per above schematic but with no
toggle switches and housings attachd is available as P/NATI-010998-XX.
Orange*
Green
Blue
White
Red
Black