M
CB
3
Installation Manual
Page 44
Troubleshoot Menu
Machine Voltage -
Displays machine voltage.
Fault Log - Records history of fault occurrences.
Records relevant information regarding a fault including time of fault and fault code.
Press in the multi-switch to enter the log. Rotate the multi-switch to view fault entries.
Press the power switch up while viewing fault entries to display the fault description.
Refer to Appendix B for specific fault code information.
Clear Fault Log - Clears all history in the fault log.
Press in the multi-switch to clear the fault log.
LCD/LED Test
Tests for LCD brightness, contrast, and light or
dark pixels. Lights LED's in sequence.
Press in the multi-switch to enter the LCD/LED
test.
Rotate the left multi-switch to adjust the
brightness.
Rotate the right multi-switch to adjust the
contrast.
Technical Setup - Troubleshoot