M
CB
3
Installation Manual
Page 31
Valve Setup Menu
The type of valve used is selected from the
initial Technical Setup Menu.
Selections are PC, PT, or PV.
PC - Proportional Current
PT - Proportional Time
PV - Proportional Voltage
Toggle the multi-switch to highlight Valve Setup. Rotate the left and right multi-switch to
select PV, PC, or PT.
Each valve type has its individual characteristics.
The PT valve, sometimes referred to as on/off or "bang-bang" valve is not a true proportional
valve. It can only be turned on or off. The proportionality is achieved by rapidly turning the
valve on and off over time at varying duty rates.
The PC and PV valves are proportional spool valves and can take full advantage of the
receivers proportional electronics.
A common PV valve is the Danfoss PVG32, which is a pilot operated proportional valve.
Once the valve type is selected, press in the multi-switch to enter additional Valve Setup
options.
Menu items will appear depending on the type of valve selected. If both sides have the
same valve, menus specific to that valve will appear. If different valves are selected for
each side, all menu items will appear.
5.5
Technical Setup - Valve
Technical Setup Menu
< Exit >
System Setup
Valve Setup
Custom Setup
PV
PV