M
CB
3
Installation Manual
Page 28
System Setup Menu
X-Couple Setup - Cross Coupling Setup
Setup enables entry of geometry for cross
coupling calculations.
Geometry will be determined by machine
architecture selection.
For measurement accuracy, ±.006 m, ±0.25
in., ±0.02 ft is sufficient. Ensure the units of
measure are correct.
Lift and Tilt:
Measure the horizontal distance
between the left sensor and the center pivot
point. Scroll the left multi-switch to enter the
measurement.
Measure the horizontal distance between the
right sensor and the center pivot point. Scroll
the right multi-switch to enter the measurement.
On a traditional dozer configuration, the left
receiver will control the lift and will be mounted
over the pivot point on the blade. If so, the distance entered for the left side will be "0".
Push in the multi-switch to exit the setup screen.
Lift and Lift:
Use the centered or operating
blade side shift position prior to measurement.
Measure the horizontal distance between the
left sensor and the left side pivot point. Highlight
the left number and scroll the left multi-switch to
enter the measurement.
Measure the horizontal distance between the
right sensor and the right side pivot point.
Highlight the right number and scroll the right multi-switch to enter the measurement.
Measure the horizontal distance between the right side pivot point and the left side pivot
point. Toggle either multi-switch sideways to highlight the center number. Use the same
side switch to enter the measured value.
Push in the multi-switch to exit the setup screen.
Technical Setup - System
5.4
X- Couple Setup
Ft
<Push> to Return
3.250
X
^
X
^
3.250
2.250
X- Couple Setup
Ft
<Push> to Return
3.250
X
^
X
0.0
System Setup Menu
X-Couple Enable
X-Couple Setup
Slope
Ctl%Dsp DB