Field
Description
Possible values:
•
Both
(default value): For incoming and outgoing calls
(bidirectional).
•
Incoming
: For incoming calls.
•
Outgoing
: For outgoing calls.
Associated Line
Select the line or SIP account via which the calls are to be
routed.
Possible values:
•
PRI
: Restricts the call to the selected PRI interface.
•
BRI
: Restricts the call to the selected BRI interface.
•
FXO
: Restricts the call to the selected FXO interface.
•
FXS
: Restricts the call to the selected FXS interface.
•
<SIP Account>
: Restricts the call to the selected SIP ac-
count.
Local Address
Enter the internal number (e.g. extension or PABX number). For
incoming calls, the signalled Called Party Number (corresponds
in the menu to the External Address field) is translated to the
Local Address. For outgoing calls, the signalled Calling Party
Number (corresponds in the menu to the Local Address field)
is translated to the External Address.
Numerical and alphanumerical characters are permissible.
?
is a placeholder for an arbitrary digit.
Note Local Address and External Address must contain the
same number of wildcards.
External Address
The External Address is not shown if the field Associated
Line =
<SIP Account>
.
Enter the external number (e.g. ISDN MSN or SIP account sub-
scriber number). For incoming calls, the signalled Called Party
Number (corresponds in the menu to the External Address
field) is translated to the Local Address. For outgoing calls, the
signalled Calling Party Number (corresponds in the menu to the
Local Address field) is translated to the External Address.
Funkwerk Enterprise Communications GmbH
13 VoIP
bintec R1xxx/R3xxx/R4xxx
409