Field
Description
rate of 192 kbps to 2312 kbps.
•
4 wire
: Four wires are used with m-pair bonding for a clock
rate of 384 kbps to 4624 kbps. This option supports 4-wire
mode under G991.2 and Globespan Enhanced Mode.
•
4 wire standard
: Four wires are used for m-pair bonding
with a clock rate of 384 kbps to 4624 kbps. This option sup-
ports 4-wire mode under G991.2 but not Globespan En-
hanced Mode.
•
4 wire IMA
: Four wires are used with IMA for a clock rate of
384 kbps to 4624 kbps.
•
6 wire
: Six wires are used with m-pair bonding for a clock
rate of 576 kbps to 6936 kbps.
•
6 wire IMA
: Six wires are used with IMA for a clock rate of
576 kbps to 6936 kbps.
•
8 wire
: Eight wires are used with m-pair bonding for a clock
rate of 768 kbps to 9248 kbps.
•
8 wire IMA
: Eight wires are used with IMA for a clock rate
of 768 kbps to 9248 kbps.
Additional Wire Pairs
Only for Wire Mode =
4 wire
,
4 wire standard
,
4 wire
IMA
,
6 wire
,
6 wire IMA
.
For Wire Mode =
4 wire
,
4 wire standard
or
4 wire
IMA
the second pair of wires is defined here.
For Wire Mode =
6 wire
or
6 wire IMA
the second and third
pairs of wires are defined here.
Wire pairs already used in defined connections are not available
for selection. If these continue to be used for this SHDSL con-
nection, the existing connection must first be terminated.
Requested Rate
Only for Clock Rate =
Fixed
.
Select which speed should be used.
Line Speed Interval
Only for Clock Rate =
Adaptive
.
Under Minimum select the minimum clock rate and under Max-
imum select the maximum clock rate for the connection.
6 Physical interfaces