158
Upgrade and Maintenance Manual
RX300
S7
Hard disk drives / solid state drives
●
Under no circumstances should you remove an HDD / SSD module
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD / SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
●
All HDD / SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.3.4.1
Required tools
●
Preliminary and concluding steps: tool-less
●
Replacing a 2.5-inch HDD / SSD module: tool-less
7.3.4.2
Preliminary steps
Perform the following procedures:
Ê
"Opening the rack door" on page 64
Ê
"Locating the defective server" on page 56
Ê
Locate the defective HDD / SSD module as described in section
"Local
diagnostic indicators on the front" on page 60
.
Only applicable for removing intact HDD / SSD modules:
Ê
Before removing a non-defective HDD / SSD module, put the drive into
"Offline" mode using your RAID configuration software.
7.3.4.3
Removing a 2.5-inch HDD / SSD module
Ê
Remove the HDD / SSD module to be replaced from the server as described
in section
"Removing a 2.5-inch HDD / SSD module" on page 155
.
7.3.4.4
Installing a 2.5-inch HDD / SSD module
Ê
Install the new HDD / SSD module into the empty drive bay as described in
section
"Installing 2.5-inch HDD / SSD modules" on page 151
Summary of Contents for PRIMERGY RX300 S7
Page 6: ...Upgrade and Maintenance Manual RX300 S7 ...
Page 26: ...26 Upgrade and Maintenance Manual RX300 S7 ...
Page 30: ...30 Upgrade and Maintenance Manual RX300 S7 Introduction ...
Page 42: ...42 Upgrade and Maintenance Manual RX300 S7 Before you start ...
Page 116: ...116 Upgrade and Maintenance Manual RX300 S7 Basic software procedures ...
Page 136: ...136 Upgrade and Maintenance Manual RX300 S7 Power supply ...
Page 176: ...176 Upgrade and Maintenance Manual RX300 S7 Hard disk drives solid state drives ...
Page 186: ...186 Upgrade and Maintenance Manual RX300 S7 System fan ...
Page 334: ...334 Upgrade and Maintenance Manual RX300 S7 Processors ...
Page 406: ...406 Upgrade and Maintenance Manual RX300 S7 Accessible drives ...
Page 498: ...498 Upgrade and Maintenance Manual RX300 S7 System board and components ...
Page 524: ...524 Upgrade and Maintenance Manual RX300 S7 Conversion configurations ...
Page 560: ...560 Upgrade and Maintenance Manual RX300 S7 Appendix ...