Processors
Figure 151: Opening the load plate (B)
Ê
Fully open the load plate.
V
CAUTION!
Be careful not to touch or bend the spring contacts on the processor
socket!
Ê
Make sure that the load plate is in the fully open position.
Ê
Use a magnifying glass (recommended) to inspect the socket spring
contacts for damages from different angles. Do not use the spare system
board if any irregularities are visible. Possible damages:
– Contact spring is bent backwards upon itself
– Contact spring tip position is shifted or out of alignment