RX300 S7
Upgrade and Maintenance Manual
319
Processors
V
CAUTION!
Processors are extremely sensitive to electrostatic discharge and
must be handled with care. After a processor has been removed from
its protective sleeve or from its socket, place it upside down on a
nonconducting, antistatic surface. Never push a processor over a
surface.
11.4.3.2 Installing the processor
Figure 172: Installing the processor
Ê
Hold the processor with your thumb and index finger.
Ê
Make sure that the four notches on the processor align with the posts on the
socket (see close-up).