RX300 S7
Upgrade and Maintenance Manual
71
Basic hardware procedures
Ê
Shut down the server and remove external cables as described in section
"Preliminary steps" on page 68
.
Ê
Unlatch and pull the server out of the rack as described in section
"Extending
the server out of the rack" on page 69
.
Figure 12: Removing the server from the rack
Ê
Release the locking bars on both rails (1).
Ê
Lift up the front of the server as shown so that the front and middle rack
mounting bolts are disengaged from the mounting points on the telescopic
rails.
Ê
Lift the server out of the rear mounting points (3) and place it on an even
surface.