Basic hardware procedures
4.9
Connecting the server to the power source
The PRIMERGY RX300 S7 server is equipped with up to two standard power
supplies unit that automatically adjusts to any mains voltage in the range of
100 VAC to 240 VAC or up to two DC hot-plug power supply unit that adjusts
automatically to any power voltage in the range from -40.5 V to -57 V.
Connecting power cords to the mains
V
CAUTION!
The power supply automatically adjusts to any mains voltage in the
range of 100 VAC to 240 VAC. You may only operate the server if its
rated voltage range corresponds to the local mains voltage.
Figure 22: Securing power cord
Ê
Connect the power connector (1) to the power supply unit.
Ê
Close the cable clamp around the power cord (2) and lock the cable
clamp (3) to secure the power cord.
Ê
Connect the mains plug to a grounded mains outlet in the in-house power
supply network or a power outlet of the rack socket strip (see also
"PRIMECENTER Rack System" assembly guide).
Summary of Contents for PRIMERGY RX300 S7
Page 6: ...Upgrade and Maintenance Manual RX300 S7 ...
Page 26: ...26 Upgrade and Maintenance Manual RX300 S7 ...
Page 30: ...30 Upgrade and Maintenance Manual RX300 S7 Introduction ...
Page 42: ...42 Upgrade and Maintenance Manual RX300 S7 Before you start ...
Page 116: ...116 Upgrade and Maintenance Manual RX300 S7 Basic software procedures ...
Page 136: ...136 Upgrade and Maintenance Manual RX300 S7 Power supply ...
Page 176: ...176 Upgrade and Maintenance Manual RX300 S7 Hard disk drives solid state drives ...
Page 186: ...186 Upgrade and Maintenance Manual RX300 S7 System fan ...
Page 334: ...334 Upgrade and Maintenance Manual RX300 S7 Processors ...
Page 406: ...406 Upgrade and Maintenance Manual RX300 S7 Accessible drives ...
Page 498: ...498 Upgrade and Maintenance Manual RX300 S7 System board and components ...
Page 524: ...524 Upgrade and Maintenance Manual RX300 S7 Conversion configurations ...
Page 560: ...560 Upgrade and Maintenance Manual RX300 S7 Appendix ...