Power supply
Ê
"Locating the defective server" on page 56
6.1.3
Removing a PSU dummy module
Figure 27: Removing the PSU dummy module
Ê
Press in on both locking latches on the PSU dummy module (1) and carefully
detach the dummy module from its slot (2).
Ê
Remove the dummy module from its slot.
V
CAUTION!
Keep the dummy cover for future use. If a power supply module is
removed and not immediately replaced by a new one, a PSU dummy
cover must be replaced in the slot to comply with applicable EMC
regulations and satisfy cooling requirements.