90
Upgrade and Maintenance Manual
RX100
S8
Basic software procedures
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.
Executing the fan test via ServerView Operations Manager
Ê
Open the ServerView Operations Manager and log in.
Ê
Under
Administration
select
Server Configuration
.
Ê
In the hierarchy tree of the
Server list
tab, select the server to be configured.
Ê
In the right-hand side of the window, specify the details on the selected
server and confirm your entries by clicking
GO...
.
In the left-hand section of the window, the
Configuration
tab is being
activated.
Ê
In the navigation area of the
Configuration
tab, select
Other Settings
.
Ê
Under
Daily Fan Test
, set the daily fan test time to a few minutes from the
current time. (Ensure to note down your previous setting.)
Ê
Click
Save Page
.
The fan test will be started at the specified time.
Ê
After the fan test is complete, restore the time setting to its initial value and
click
Save Page
.
I
For more detailed information, refer to the "ServerView Operations
Manager" user guide.
For the Japanese market: Executing the fan test via Chassis ID Prom Tool
I
Please follow the instructions provided separately.
Summary of Contents for PRIMERGY RX100 S8
Page 18: ...Upgrade and Maintenance Manual RX100 S8 Contents ...
Page 62: ...62 Upgrade and Maintenance Manual RX100 S8 Basic hardware procedures ...
Page 148: ...148 Upgrade and Maintenance Manual RX100 S8 Hard disk drives solid state drives ...
Page 154: ...154 Upgrade and Maintenance Manual RX100 S8 Fans ...
Page 270: ...270 Upgrade and Maintenance Manual RX100 S8 System board and components ...
Page 278: ...278 Upgrade and Maintenance Manual RX100 S8 Cables ...