146
Upgrade and Maintenance Manual
RX100
S8
Hard disk drives / solid state drives
Figure 79: Removing the 3.5-inch HDD backplane
Ê
Pull the HDD backplane upward until the three hooks disengage (see
circles).
Ê
Take out the HDD backplane.
7.3.5.3
Installing the new 3.5-inch HDD backplane
Figure 80: Installing the 3.5-inch HDD backplane
Ê
Position the HDD backplane on the three hooks (see circles).
Ê
Push the HDD backplane downward. Make sure that the lower cant of the
HDD backplane fits in the guides (A).
V
CAUTION!
Ensure that none of the cables are strained or damaged!