80
Upgrade and Maintenance Manual
RX100
S8
Basic software procedures
5.2.9
Verifying the memory mode
If a memory module fails, the server will reboot and the defective module will be
disabled. As a result, the current operation mode (e.g. Mirrored Channel mode)
may no longer be available due to a lack of identical memory module pairs. In
this case, the operation mode will automatically revert to Independent Channel
Mode.
I
For detailed information on memory operation modes available for your
server, refer to section
"Modes of operation" on page 206
.
After replacing the defective module(s) the memory operation mode is
automatically reset to its original state. It is recommended to verify that the
operation mode has been correctly.
Ê
Enter the BIOS.
Ê
Select the
Advanced
menu.
Ê
Under
Memory Status
verify that none of the memory modules are marked as
Failed
.
Ê
Save your changes (if applicable) and exit the BIOS.
I
For detailed information on how to access the BIOS and modify settings,
refer to the corresponding BIOS Setup Utility reference manual.
5.2.10 Verifying the system time settings
I
This task only applies to Linux environments.
After the system board has been replaced, the system time is set automatically.
By default, the RTC (Real Time Clock) time standard is set as the local time.
If a Linux OS is used and the hardware clock has been configured as UTC
(Universal Time, Coordinated) in the operating system, the BMC local time may
not be mapped correctly.
Ê
After replacing the system board, ask the system administrator whether the
RTC or UTC time standard is to be used as system time.
I
If the system time (RTC) is set to UTC, the SEL (System Event Log)
time stamps may differ from the local time.
Ê
Enter the BIOS.
Summary of Contents for PRIMERGY RX100 S8
Page 18: ...Upgrade and Maintenance Manual RX100 S8 Contents ...
Page 62: ...62 Upgrade and Maintenance Manual RX100 S8 Basic hardware procedures ...
Page 148: ...148 Upgrade and Maintenance Manual RX100 S8 Hard disk drives solid state drives ...
Page 154: ...154 Upgrade and Maintenance Manual RX100 S8 Fans ...
Page 270: ...270 Upgrade and Maintenance Manual RX100 S8 System board and components ...
Page 278: ...278 Upgrade and Maintenance Manual RX100 S8 Cables ...