RX100 S8
Upgrade and Maintenance Manual
79
Basic software procedures
I
For detailed information on how to access the BIOS and modify settings,
refer to the corresponding BIOS Setup Utility reference manual.
Configuring boot watchdog settings using the iRMC web frontend
Ê
Enter the ServerView iRMC web frontend.
Ê
Select the
Server Management
menu.
Ê
Under
Watchdog Settings
ensure that the check box next to Boot Watchdog is
selected. From the drop down list choose
Reset
and specify the desired
timeout delay.
Ê
Click
Apply
for the changes to take effect.
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.
5.2.8
Enabling replaced components in the system BIOS
When a processor, an expansion card, or a memory module fails, the defective
component will be set to
Disabled
or
Failed
in the system BIOS. The server will
then reboot with only the intact hardware components remaining in the system
configuration. After replacing the defective component, it needs to be re-
enabled in the system board BIOS.
Ê
Enter the BIOS.
Ê
Select the
Advanced
menu.
Ê
Select the status menu of the desired component:
– Processors:
CPU Status
I
This option is only available for multi-processor systems.
– Memory:
Memory Status
– Expansion cards:
PCI Status
Ê
Reset replaced components to
Enable
.
Ê
Save your changes and exit the BIOS.
I
For detailed information on how to access the BIOS and modify settings,
refer to the corresponding BIOS Setup Utility reference manual.
Summary of Contents for PRIMERGY RX100 S8
Page 18: ...Upgrade and Maintenance Manual RX100 S8 Contents ...
Page 62: ...62 Upgrade and Maintenance Manual RX100 S8 Basic hardware procedures ...
Page 148: ...148 Upgrade and Maintenance Manual RX100 S8 Hard disk drives solid state drives ...
Page 154: ...154 Upgrade and Maintenance Manual RX100 S8 Fans ...
Page 270: ...270 Upgrade and Maintenance Manual RX100 S8 System board and components ...
Page 278: ...278 Upgrade and Maintenance Manual RX100 S8 Cables ...