RX100 S8
Upgrade and Maintenance Manual
107
Power supply
6.4.1
Preliminary steps
Ê
"Disabling BitLocker functionality" on page 63
Ê
"Shutting down the server" on page 45
Ê
"Disconnecting the server from the mains" on page 46
Ê
"Getting access to the component" on page 47
6.4.2
Removing the standard power supply unit
Ê
Remove the power supply unit as described in section
"Removing the
defective standard power supply unit" on page 93
.
Figure 36: Removing the adapter plate
Ê
Remove the screw (see circle) which attach the adapter plate of the power
supply unit to the housing.
Ê
Push the adapter plate a few centimeters inward to detach it from the two
bolts (see close-ups).
Ê
Remove the adapter plate.