Hard disk drives / solid state drives
7.3.4
Replacing a 3.5-inch HDD module
V
CAUTION!
●
Only remove an HDD module during operation if the drive is not
currently being accessed. Observe the indicators on the HDD
module, see section
"Indicators on the hot-plug HDD module" on
page 293
.
●
Under no circumstances should you remove an HDD module while
the system is in operation if you are not sure that the drive is operated
by a RAID controller and belongs to a disk array that is operating in
RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD module can only be replaced during operation in conjunction
with a corresponding RAID configuration.
●
All HDD modules (drives) must be uniquely identified so that they can
be reinstalled in their original bays later. If this is not done, existing
data can be lost.
7.3.4.1
Preliminary steps
Ê
"Locating the defective server" on page 43
Ê
"Locating the defective component" on page 45
Only applicable for removing intact HDD modules:
Ê
Before removing a non-defective HDD module, put the drive into "Offline"
mode using your RAID configuration software.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
tool-less
Summary of Contents for PRIMERGY RX100 S8
Page 18: ...Upgrade and Maintenance Manual RX100 S8 Contents ...
Page 62: ...62 Upgrade and Maintenance Manual RX100 S8 Basic hardware procedures ...
Page 148: ...148 Upgrade and Maintenance Manual RX100 S8 Hard disk drives solid state drives ...
Page 154: ...154 Upgrade and Maintenance Manual RX100 S8 Fans ...
Page 270: ...270 Upgrade and Maintenance Manual RX100 S8 System board and components ...
Page 278: ...278 Upgrade and Maintenance Manual RX100 S8 Cables ...