
RX100 S8
Upgrade and Maintenance Manual
139
Hard disk drives / solid state drives
7.3
3.5-inch HDD configurations
7.3.1
Equipping the 3.5-inch HDD bays
– If only one HDD module is installed, the HDD module will be installed in the
left bay (seen from the front) and dummy modules must be installed in the
free bays.
– Installing different capacities, install the biggest capacity first.
– Installing different rotating speed, install the fastest rotating speed first.
Mounting order
Figure 73: Mounting order with up to four 3.5-inch HDDs
HDD naming scheme
Figure 74: Naming scheme with up to four 3.5-inch HDDs
I
The HDD numbering as listed in the ServerView RAID Manager differs
from the HDD mounting order:
Position
Logical drive number ServerView RAID Manager display name
[1]
0
HDD vendor name (0)
[2]
1
HDD vendor name (1)
[3]
2
HDD vendor name (2)
[4]
3
HDD vendor name (3)
Summary of Contents for PRIMERGY RX100 S8
Page 18: ...Upgrade and Maintenance Manual RX100 S8 Contents ...
Page 62: ...62 Upgrade and Maintenance Manual RX100 S8 Basic hardware procedures ...
Page 148: ...148 Upgrade and Maintenance Manual RX100 S8 Hard disk drives solid state drives ...
Page 154: ...154 Upgrade and Maintenance Manual RX100 S8 Fans ...
Page 270: ...270 Upgrade and Maintenance Manual RX100 S8 System board and components ...
Page 278: ...278 Upgrade and Maintenance Manual RX100 S8 Cables ...