RX100 S8
Upgrade and Maintenance Manual
219
Processor
11.3
Replacing the heat sink
11.3.1 Preliminary steps
Ê
"Locating the defective server" on page 43
Ê
"Shutting down the server" on page 45
Ê
"Disconnecting the server from the mains" on page 46
Ê
"Getting access to the component" on page 47
Ê
"Removing a riser module" on page 58
11.3.2 Removing the defective heat sink
Ê
Remove the heat sink as described in section
"Removing the heat sink" on
page 213
.
Ê
Remove the residual thermal paste from the processor surface.
Ê
Clean the processor surface using a lint-free cloth.
11.3.3 Installing the new heat sink
Ê
Remove the protective cover on the underside of the heat sink.
V
CAUTION!
Do not touch the thermal paste on the underside of the heat sink.
Ê
Install the heat sink as described in section
"Installing the heat sink" on
page 218
.
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver