RX100 S8
Upgrade and Maintenance Manual
143
Hard disk drives / solid state drives
7.3.3.2
Removing a 3.5-inch HDD module
Ê
Pinch the green locking clips and open the locking lever (see figure
76
).
Ê
Pull the HDD module out a few centimeters.
Ê
Wait about 30 seconds to allow the hard disk drive to spin down.
I
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the hard disk drive to come
to a stop.
Ê
Pull the HDD module completely out of its bay.
7.3.3.3
Installing a 3.5-inch dummy module
V
CAUTION!
If the removed HDD module is not replaced immediately, always replace
a dummy module into the unused HDD bay to comply with applicable
EMC regulations and satisfy cooling requirements.
Figure 78: Installing the 3.5-inch dummy module
Ê
Push the dummy module into the empty bay until it engages.
7.3.3.4
Concluding steps
No steps needed.