CX2550/60/70 M4
Upgrade and Maintenance Manual
287
System board and components
I
For detailed information on how to access the BIOS and modify
settings, see the corresponding BIOS Setup Utility reference manual.
Ê
"Suspending BitLocker functionality" on page 71
Ê
"Shutting down the server node" on page 50
Ê
If applicable, remove all external cables from the server node.
9.3.2.2
Removing the TPM
Ê
"Removing the system board" on page 309
Ê
Lay the system board on a soft, antistatic surface with its component side
facing down.
Figure 179: Removing the TPM screw (example)
Ê
Locate the slotted lower end of the TPM screw (1).
Ê
Carefully loosen the TPM screw using a thin slotted screw driver (e.g.
watchmaker's screw driver) or the dedicated TPM screw driver (for
Japan) (2).
V
CAUTION!
Ensure to turn the screw
clockwise
in order to remove it!
Summary of Contents for PRIMERGY CX2550 M4
Page 6: ...6 Upgrade and Maintenance Manual CX2550 60 70 M4 ...
Page 20: ...Upgrade and Maintenance Manual CX2550 60 70 M4 Contents ...
Page 46: ...46 Upgrade and Maintenance Manual CX2550 60 70 M4 Important information ...
Page 70: ...70 Upgrade and Maintenance Manual CX2550 60 70 M4 Basic hardware procedures ...
Page 114: ...114 Upgrade and Maintenance Manual CX2550 60 70 M4 Expansion cards and OCP mezzanine cards ...
Page 182: ...182 Upgrade and Maintenance Manual CX2550 60 70 M4 Expansion cards and OCP mezzanine cards ...
Page 192: ...192 Upgrade and Maintenance Manual CX2550 60 70 M4 Main memory Figure 85 Memory dummy module ...
Page 204: ...204 Upgrade and Maintenance Manual CX2550 60 70 M4 Main memory ...
Page 320: ...320 Upgrade and Maintenance Manual CX2550 60 70 M4 System board and components ...
Page 356: ...356 Upgrade and Maintenance Manual CX2550 60 70 M4 GPGPU extension tray ...
Page 418: ...418 Upgrade and Maintenance Manual CX2550 60 70 M4 SXM2 extension tray ...
Page 454: ...454 Upgrade and Maintenance Manual CX2550 60 70 M4 Appendix ...